Implementasi dan Analisis Kinerja PJU Tenaga Surya untuk Peningkatan Kualitas Pencahayaan di Kawasan Technopark UPN “Veteran” Jawa Timur
DOI:
https://doi.org/10.31599/75vnea30Abstract
Poor lighting at the Technopark access of UPN "Veteran" Jawa Timur creates security risks and energy inefficiency. This study aims to implement an energy-independent Solar Street Light (PJU-TS) system to support the Green Campus vision. Using applied research methods, the activities included needs analysis, system design, physical installation of four All-in-One PJU-TS units, and performance evaluation. Post-installation results showed a drastic increase in average light intensity from <1 Lux to >10 Lux, meeting SNI 7391:2008 standards. The light sensor-based automatic control system proved effective in managing dusk-to-dawn operations, optimizing LiFePO4 battery usage. This implementation successfully eliminated blind spots, significantly improved the academic community's sense of security, and serves as a model for eco-friendly and energy-efficient campus infrastructure.